User’s Guide
CPSMM-120
Single-Slot Master Management Module
Transition Networks CPSMM-120 Single-Slot master
management module enables network management of a
single PointSystem™ chassis (CPSMC0200-2x0,
CPSMC0800-100, CPSMC13xx-100, CPSMC18xx-xxx
and CPSMC19xx-100) and any installed media converter
slide-in-modules.
The CPSMM-120 includes Transition Networks
CPSMM100 firmware embedded in the module, which
can be accessed via the DB-9 serial port or the 10Base-T
RJ-45 Ethernet port.
Installing the CPSMM-120 . . . . . .3
Network Management . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . .4
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
CPSMM-120
Operation -- continued
LEDs indications -- continued
Network Management
CPSMM100 Firmware
PWR
LNK
(Power)
(Link)
The management module is
receiving power from the chassis.
The Transition Networks CPSMM100 firmware is embedded in the CPSMM-
120 management module. The firmware includes:
TX PWR
RX LNK
A link has been established via the
DB-9 serial port or the RJ-45
Ethernet port.
•
•
•
•
a Command-Line Interface (CLI),
a Telnet server,
R
E
S
E
T
a Web browser, and
an SNMP agent.
RX
TX
(Receive)
(Transmit)
The management module is
receiving data via the DB-9 serial
port or the RJ-45 Ethernet port.
Each of these applications can be accessed either through the module’s DB-9
serial port or RJ-45 Ethernet port, which allows the network administrator to
monitor and control the network from an attached terminal or from a remote
location.
The management module is transmitting data via the
DB-9 serial port or the RJ-45 Ethernet port.
Reset Switch
The CPSMM-120 has a reset switch which only resets the management
module, not the entire chassis in which the module has been installed.
FocalPoint™ 2.0 Management Application
Transition Networks FocalPoint™ 2.0 management application can be
installed in a networked computer to provide a graphical user interface to
monitor the network. The version on the enclosed CD supports all features of
the enclosed CPSMM100 firmware as well as all Transition Networks slide-in-
modules that are available at the time the CD was produced.
Technical Specification
For use with Transition Networks Model CPSMM-120 or equivalent.
Standards
CISPR 22:1993; Class A; CE Mark
3.4” x 0.86” x 5.0” (86 mm x 22 mm x 127 mm)
3 oz. (91 g) (approximate)
Dimensions
Weight
NOTE: For detailed information on how to:
•
•
•
Set up and configure a network using the CPSMM100 firmware.
Use the command-line interface, Telnet server, or Web browser.
Install and use the FocalPoint™ 2.0 management application.
Power Consumption
MTBF
2.4 Watts.
243,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,241,000 hours (Bellcore7 V5.0)
Environment
Tmra*:
0 to 60°C (32 to 140°F )
-20 to 85°C (-4 to 185°F)
10 to 90%, non condensing
0 to 10,000 feet
Storage Temp:
Humidity:
Altitude:
See the FocalPoint™ 2.0 Management Application and CPSMM100 Firmware
User’s Guide on the enclosed application CD. It can also be viewed on the
Warranty
Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for these management
modules depend on the physical characteristics and the installation configuration
of the Transition Networks PointSystem™ chassis in which the modules will be
installed. See the user’s guide for the chassis in which these modules will be
installed for temperature-related installation constraints.
Operation
LED Indicators
The CPSMM-120 management module has four status LEDs, which are
used to monitor the operation of the management module in the
network.
WARNING: Visible and invisible laser radiation when open. Do not stare into
the beam or view the beam directly with optical instruments. Failure to observe
this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.
The information in this user’s guide is subject to change. The most up-to-date
5
24-hour Technical Support: 1-800-260-1312 - International: 00-1-952-941-7600
4
CPSMM-120
Troubleshooting
If the management module fails, isolate and correct the failure by determining
the answers to the following questions and then taking the indicated action:
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada:
International:
1-800-260-1312
00-1-952-941-7600
1.
Press the Reset button on the management module. Does the
fault resolve itself?
NO
Transition Now
•
Proceed to step 2.
Chat live via the Web with Transition Networks Technical Support.
2.
Is the PWR (power) LED on the management module
illuminated?
NO
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
•
•
•
Is the management module inserted properly into the chassis?
Is the chassis properly connected to the external power source.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
YES
•
Proceed to step 3.
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
3.
telephone:
toll free:
fax:
952-941-7600
800-526-9267
952-941-2322
YES
•
Proceed to step 4.
Declaration of Conformity
Name of Mfg:
Transition Networks
NOTE: To Isolate faults involving data transmission, Please see the
“Troubleshooting” section of the FocalPoint™ 2.0 Management
Application and CPSMM100 Firmware User’s Guide on the enclosed
application CD. It can also be viewed on the Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
CPSMM-120 Single-Slot Master Management Module
CPSMM-120
Model:
Part Number:
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the CPSMM-120 to which this declaration refers are in
conformity with the following standards.
CISPR 22:1993; EN 55022:1998; Class A; EN 55024:1998; FCC Part 15 Subpart B;
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
May, 2007
Stephen Anderson, Vice-President of Engineering
Date
7
24-hour Technical Support: 1-800-260-1312 - International: 00-1-952-941-7600
6
Compliance Information
CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de
prende les measures spécifiques appropriées.
In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will
accept post usage returns of this product for proper disposal. The contact
information for this activity can be found in the 'Contact Us' portion of this
document.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2001, 2004-2005 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means - graphic, electronic, or mechanical - without written permission from Transition
Networks.
Printed in the U.S.A.
33203.F
|